Troubleshooting the interface module failure, Symptom, Solution – H3C Technologies H3C SecPath F1000-E User Manual

Page 68

background image

60

2.

Verify that the working environment of the firewall is well ventilated.

3.

If the temperature inside the firewall exceeds 50°C (122°F), the following information appears on
the configuration terminal:

%Jun 28 10:27:27:653 2007 H3C DRVMSG/3/Temp2High:

Environment temperature too high in Slot 0, index is 1.

#Jun 28 10:27:28:432 2007 H3C DEV/1/BOARD TEMPERATURE UPPER:

Trap 1.3.6.1.4.1.2011.2.23.1.12.1.16:frameIndex is

0, slotIndex 0.0

%Jun 28 10:27:28:433 2007 H3C DEV/4/BOARD TEMP TOOHIGH:

Board temperature is too high on Frame 0 Slot 0, type is RPU.

4.

Use the display environment command to examine whether the temperature inside the firewall is

rising. If the temperature inside the firewall exceeds 90°C (194°F), power off the firewall
immediately and contact your local sales agent.
For more information about the display environment command, see the firewall command
references.

Troubleshooting the interface module failure

Symptom

After an interface module is installed and the firewall is powered on, the LEDs on the interface module
panel indicate the interface module is not operating properly.

Solution

1.

Verify that the correct interface module cable is used.

2.

Verify that the interface module cable is correctly connected.

3.

Use the display interface command to examine whether the interfaces of the interface module
have been correctly configured and are operating properly.