Required tools, Installation procedure – H3C Technologies H3C SecPath F1000-E User Manual
Page 36
28
Installing a lightning protector for a network port
The lightning protector for a network port is only applicable to a copper Ethernet port.
If part of the network cable of a copper Ethernet port must be routed outdoors, connect a lightning
protector to the cable before you plug the cable into the port.
The following lightning protector for network ports is available for the firewall:
Type Port
description
Maximum discharge current
(8/20μs waveform)
Output voltage
1000M port lightning
protector
Single port
3 kA
•
Core-core < 15 V
•
Core-ground < 350 V
Required tools
Flat-blade screwdriver
Phillips screwdriver
Diagonal pliers
Multimeter
Installation procedure
IMPORTANT:
Read the instructions for the lightning protector carefully before you install it.
To install a lightning protector:
1.
Use a double-faced adhesive tape to stick the lightning protector onto the firewall chassis, and
make sure it is as close to the grounding screw of the firewall as possible.
2.
Measure the distance between the protector and the grounding screw of the firewall, cut the
ground wire of the protector as appropriate, and securely tighten the ground wire to the
grounding screw of the firewall.
3.
Use the multimeter to measure whether the ground wire of the protector contacts well with the
grounding screw of chassis.
4.
Insert the outdoor network cable into the protector's IN end, and the cable connected to the
firewall into the OUT end, and check the indicators on the lightning protector to verify that the
connection is correct.
5.
Use nylon ties to bundle the cables neatly.