Lightning protection – H3C Technologies H3C SecPath F1000-E User Manual
Page 18

10
Figure 12 Attaching an ESD-preventive wrist strap
(1) Alligator clip
(2) Lock
(3) ESD-preventive wrist strap
EMI
All electromagnetic interference (EMI) sources, from outside or inside of the firewall and application
system, adversely affect the firewall in a conduction pattern of capacitance coupling, inductance
coupling, electromagnetic wave radiation, or common impedance (including grounding system)
coupling. To prevent EMI, perform the following steps:
•
Take measures against interference from the power grid.
•
Do not use the firewall together with the grounding equipment or lightning-prevention equipment
of power equipment, and keep the firewall far away from them.
•
Keep the firewall far away from high-power radio launchers, radars, and equipment with high
frequency or high current.
•
Use electromagnetic shielding when necessary.
Lightning protection
To protect the firewall from lightning better, do as follows:
•
Make sure the chassis is properly grounded. For how to ground the firewall, see "
."
•
Make sure the grounding terminal of the AC power receptacle is properly grounded.
•
Install a lightning protector at the input end of the power supply to enhance lightning protection
capability. For more information, see "