Cooling system of the S5560-30S-EI and S5560-54S-EI
switches

The S5560-30S-EI and S5560-54S-EI switches use fixed fan trays and left-to-right aisles for air ventilation.
Ambient air flows in through the air vents in the left side panel, circulates through the chassis and the

power modules, and exhausts through the air vents in the right side panel and air vents of the power

module fan trays, as shown in

Figure 81

.

The following figure uses the S5560-30S-EI switch as example.

Figure 81 Airflow through the S5560-30S-EI switch

IMPORTANT:

The chassis and the power modules use separate air aisles. Make sure both aisles are not blocked.