Configuration terminal problems

If the configuration environment setup is correct, the configuration terminal displays booting information
when the switch is powered on. If the setup is incorrect, the configuration terminal displays nothing or

garbled text.

No terminal display

Symptom

The configuration terminal displays nothing when the switch is powered on.

Solution

To resolve the problem:

1.

Verify that the power module is supplying power to the switch.

2.

Verify that the console cable is correctly connected.

3.

Verify that the console cable does not have any problems and the terminal settings are correct.

4.

If the problem persists, contact H3C Support.

Garbled terminal display

Symptom

Terminal display is garbled.

Solution

To resolve the problem:

1.

Verify that the following settings are configured for the terminal:

{

Baud rate—9,600.

{

Data bits—8.

{

Parity—none.

{

Stop bits—1.

{

Flow control—none.

2.

If the problem persists, contact H3C Support.