beautypg.com

Hot swappable fan tray failure, Configuration terminal problems, No terminal display – H3C Technologies H3C S5560 Series Switches User Manual

Page 71

background image

62

Item

S5560-30S-

EI

S5560-54S-

EI

S5560-30F-

EI

S5560-30C-

EI

S5560-54C-

EI

S5560-54Q

S-EI

Minimum
power

consumpti
on

AC: 42
W

DC: 40

W

AC: 52
W

DC: 52

W

Single AC

input: 48
W

Dual AC

inputs: 53
W

Single DC

input: 70
W

Dual DC

inputs: 60
W

Single AC

input: 55
W

Dual AC

inputs: 57
W

Single DC

input: 49
W

Dual DC

inputs: 51
W

Single AC

input: 70
W

Dual AC

inputs: 70
W

Single DC

input: 59
W

Dual DC

inputs: 59
W

Single AC

input: 88
W

Dual AC

inputs: 85
W

Single DC

input: 77
W

Dual DC

inputs: 75
W

Maximum
power

consumpti

on

AC: 66
W

DC: 68

W

AC: 80
W

DC: 82

W

Single AC

input:

120 W

Dual AC

inputs:
123 W

Single DC

input:
146 W

Dual DC

inputs:
133 W

Single AC

input: 107

W

Dual AC

inputs:
108 W

Single DC

input: 111
W

Dual DC

inputs:
115 W

Single AC

input: 123

W

Dual AC

inputs:
123 W

Single DC

input: 127
W

Dual DC

inputs:
130 W

Single AC

input: 112

W

Dual AC

inputs:
112 W

Single DC

input: 116
W

Dual DC

inputs:
120 W

Chassis
leakage

current

complianc

e

UL60950-1, EN60950-1, IEC60950-1, GB4943

Melting
current of

power

module
fuse

AC-input:
3.15 A,

250V

DC-input:

8 A,

250V

AC-input:
3.15 A,

250V

DC-input:

8 A,

250V

AC-input:
5 A,

250V

DC-input:

8 A,

250V

AC-input:
5 A,

250V

DC-input:

8 A,

250V

AC-input:
5 A,

250V

DC-input:

8 A,

250V

AC-input:
5 A,

250V

DC-input:

8 A,

250V

Operating
temperatu

re

0°C to 45°C (32°F to 113°F)

Relative
humidity

5% to 95%, noncondensing

Fire
resistance
complianc

e

UL60950-1, EN60950-1, IEC60950-1, GB4943

This manual is related to the following products: