Removing an interface card, Verifying the installation, Connecting the psr150-a1 – H3C Technologies H3C S5560 Series Switches User Manual
Page 44
35
Figure 46 The LSWM2XGT8PM interface card installed in the switch
Removing an interface card
CAUTION:
•
Do not touch the surface-mounted components directly with your hands.
•
Do not use excessive force during the operation.
•
If no new card is to be installed, install the filler panel to prevent dust and ensure good ventilation in the
switch.
To remove an interface card:
1.
Wear an ESD wrist strap and make sure it makes good skin contact and is correctly grounded.
2.
Use a Phillips screwdriver to completely loosen the captive screw on the interface card.
3.
(Optional.) If the interface card has an ejector lever, rotate out the ejector lever.
Skip this step if the interface card does not have an ejector lever.
4.
Gently pull the interface card along the guide rails until it completely comes out of the switch
chassis.
Verifying the installation
After you complete the installation, verify that:
•
There is enough space for heat dissipation around the switch, and the rack or workbench is stable.
•
The grounding cable is securely connected.
•
The correct power source is used.
•
The power cords are correctly connected.
•
All the interface cables are cabled indoors. If any cable is routed outdoors, verify that the socket
strip with lightning protection and lightning arresters for network ports have been correctly
connected.