beautypg.com

Installing/removing a fan tray, Grounding the switch with a grounding strip – H3C Technologies H3C S5560 Series Switches User Manual

Page 30

background image

21

Figure 26 Grounding through the PE wire of the AC power cord

(1) Chassis rear panel

(2) Three-wire AC power cord

NOTE:

To guarantee the grounding effect, use the grounding cable provided with the switch to connect to the
grounding strip in the equipment room as long as possible.

Installing/removing a fan tray

CAUTION:

Install two fan trays of the same model on the switch. Do not power on the switch when it does not have
fan trays or has only one fan tray installed.

Make sure slots are installed with fan trays or blank filler panels for the device to operate.

If both fan trays fail during operation, replace them within 2 minutes while the switch is operating.

If one fan tray fails, perform either of the following tasks:

{

If the ambient temperature is not higher than 27°C (80.6°F), replace the fan tray within 24 hours and make
sure the failed fan tray is in position before the replacement.

{

If the ambient temperature is higher than 27°C (80.6°F), replace the fan tray immediately.

Only the S5560-30F-EI, S5560-30C-EI, S5560-54C-EI, S5560-30C-PWR-EI, S5560-54C-PWR-EI, and
S5560-54QS-EI switches support hot-swappable fan trays.
The switch comes with empty fan tray slots. Choose the fan tray models based on the ventilation

requirement of the site. The air flow direction varies by fan tray model.

The LSPM1FANSA has a blue handle and provides power-to-port air flow.

This manual is related to the following products: