Run all above checks, D-35 – Epson 10020 User Manual
Page 192
At the end of the test, you see a table of the results
of the test.
For example, for a 20MB hard disk with no bad tracks, you see:
BAD TRACKS ..............
0
READ ERROR TRACKS
.......
0
GOOD TRACKS
.............
2460
Press ENTER to return to the menu
Press Enter when you have viewed the table.
If the results show BAD TRACKS on your disk, it is all right
because those tracks will not be used. If, however, the results
show any READ ERROR tracks, run the destructive surface
analysis described in Appendix E
Run All Above Checks
To run all the tests on the menu in sequence, press 5 and then
Enter. When you choose this option, all checks for the hard
disk drives and controller are performed automatically in
sequential order. Although you do not start each test, you must
still supply the appropriate responses to progress from one test
to the next. The first prompt you see is:
The data on the highest physical cylinder
may be destroyed by this check.
Enter Y to start this check.
Enter N to return to the menu.
Press Y and then Enter to continue with the test.
Performing System Diagnostics
D-35