Scc x.25 line options, Local dte address, X.25 network type – Visara LINCS Configuration User Manual
Page 74: Transmit clock, Local dte address x.25 network type transmit clock

56
LINCS Configuration
707023-003
SCC X.25 Line Options
Line Options/SCC1.0
LINCS C8.2 Central Control
Line Protocol:
X.25
Local DTE Address:
_______________
X.25 Network Type:
CCITT/NET 2
Transmit Clock:
External
Link Layer Cmd/Rsp Role:
DTE
Link Layer Window Size:
2
Response Timer - T1 (.1 sec):
0100
Retry Count - N2:
10
Receive Timer - T2 (.1 sec):
1
Lowest PVC:
____
Highest PVC:
____
Lowest Incoming SVC:
____
Highest Incoming SVC:
____
Lowest Two-Way SVC:
____
Highest Two-Way SVC:
____
Lowest Outgoing SVC:
____
Highest Outgoing SVC:
____
PF: 1-Menu
7-Back
8-Forw
9-Default 10-Done
Local DTE Address
Enter the local DTE address for this LINCS node (up to 15 digits). The number should be
consistent with the network subscription number.
X.25 Network Type
Options are:
• CCITT/NET 2
• DATANET1
• TELENET or UKPSS
• GOSIP
• CCITT/CTS-WAN
Transmit Clock
This field toggles to:
External (default), 1200, 2400, 4800, 7200, 9600, 14.4 Kbps, 19.2 Kbps, 38.4 Kbps, 48 Kbps,
57.6 Kbps, 64 Kbps, 128 Kbps, 256 Kbps, 512 Kbps, 1 Mbps.
External means that an external device, for example a modem, is supplying transmit clock to
the HSC. All other choices indicate transmit clock speeds supplied by the HSC.
External also implies that this connector is providing a DTE interface, so a DTE HSC comm
cable must be installed. All other choices indicate the this connector is providing a DCE
interface and therefore require a DCE HSC comm cable.