Device options/dft, Dft local copy format, Dft local copy form feed – Visara LINCS Configuration User Manual
Page 195: 3290 field intensity

177
Chapter 13. Device Options
707023-003
Device Options/DFT
Device Options/DFT
LINCS C8.2 Central Control
DFT Local Copy Format:
Do Not Send Format Controls
DFT Local Copy Form Feed:
No Form Feeds
3290 Field Intensity:
Underscore
3290 Update Panel:
Process Host Data Before Displaying Panel
3290 DFT Password:
______________
PF: 1-Menu
7-Back 8-Forw 9-Default 10-Done
The Device Options/DFT panel will be displayed if coax devices are configured.
Note: For information on 3290 configuration options, refer to the IBM document 3290
Information Panel: Description and Reference, GA 23-0021.
DFT Local Copy Format
The choices in this field allow the enabling or disabling of local copy format controls that in
shared mode (when the printer lacks Save/Restore capability) could interfere with format
controls set up by the host application. Toggle between two options:
• Do NOT Send Format Controls - Choose this option if the host does not reset format
controls with each Begin Bracket (SNA only)
• Format Controls Enabled - Choose this option if the host does reset format controls with
each Begin Bracket, or where the printers are not operated in shared mode
DFT Local Copy Form Feed
The choices in this field allow local copy form feed to occur in one of four modes:
• No Form Feeds
• Form Feed AFTER Local Copy ONLY
• Form Feed BEFORE Local Copy ONLY
• Form Feed BEFORE and AFTER Local Copy
3290 Field Intensity
The choices in this field allow one of three intensity options for use in place of brightness on
DFT/DSL devices that don’t support brightness:
• Underscore
• Reverse Video
• None