N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522
Air, Water or Remote Service Manual

December 2014

Page 45

Symptom

Probable Cause

Possible Correction

No ice, bin full light is ON

Adjustment knob set too low

Rotate knob to first position, knob's

arrow pointing to the left of the L in

Lower (on the label)

Obstruction beneath sensor

Check for and clear any item that

might be below the sensor

Sensor recessed

Check sensor, sensor must

be flush in its holder and not

recessed.

No ice, power light on, bin full light

is OFF

Photo-eye in chute blocked

Check controller display code. If a

b, check for blockage or scale build

up on photo eyes in chute
Check for photo eye failure

Optional Smart-Board is controlling

ice level

Check Smart-Board settings.

Ice level too high

Adjustment knob set to maximum

fill

Check if knob's arrow points to

label arrow.

Sensor wire disconnected

Check for proper connection of

sensor wire to VS control board

Bin Thermostat
Symptom

Probable Cause

Possible Correction

No ice, b in code display

Bin stat is open

Check for ice on bin thermostat

capillary tube
Check for cold ambient in bin
Check continuity of bin thermostat

when capillary tube is warm,

replaced if does not close

Unit overfills, shuts off on photo-

eyes

Bin stat is stuck closed

Check position of bin thermostat

capillary tube.

Unit overfills, shuts off on photo-

eyes

Bin stat is stuck closed

Check continuity of bin thermostat

when ice is on the capillary tube,

replaced if does not open

Service Diagnosis - Optional Ice Level Controls

Vari-Smart (KVS)