N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522
Air, Water or Remote Service Manual

December 2014

Page 15

For The Installer: Remote Condenser

Locate the condenser as near as possible to the

interior location of the ice machine. Allow it plenty of

space for air and cleaning: keep it a minimum of two

feet away from a wall or other rooftop unit.

Note: The location of the condenser relative to the ice

machine is LIMITED by the specification on the prior

page.

Roof penetration. In many cases a roofing contractor

will need to make and seal the hole in the roof for the

line sets. The suggested hole diameter is 2 inches.

Meet all applicable building codes.

Roof Attachment

Install and attach the remote condenser to the roof

of the building, using the methods and practices of

construction that conform to the local building codes,

including having a roofing contractor secure the

condenser to the roof

To Remote Condenser

Power Supply from

Ice Machine

Refrigeration Quick

Connects

Pre-Charged

Refrigeration

Tubing

Remote Condenser