beautypg.com

Scotsman Prodigy Plus D Series Service Manual User Manual

Page 23

background image

N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522
Air, Water or Remote Service Manual

December 2014

Page 23

Electrical Component Details

Compressor
• Operated by the compressor contactor.

Contactor
• Operated by the controller. Line voltage coil. When

energized the Compressor indicator light will be ON.

Fan Motor(s)
• Operated by the contactor

High pressure cut out
• All models have a high pressure cut out switch that

signals the controller if the discharge pressure is too

high. It is an automatic reset.

Low pressure switch
• On remote models it controls the compressor

contactor. Will close on pressure rise, pressure rises

when liquid line valve opens.

Opens at a lower pressure.
• Air and Water cooled models use a low pressure cut

out.

Liquid line valve
• Remote only. Opened by the controller to start ice

making. Closed to shut unit off. Line voltage coil.

Controller
• Senses water, ice making, discharge pressure,

low side pressure, and auger amps. Controls

compressor contactor, fan motor, and auger motor.

Indicates status and component operation.

Transformer
• 12 volt secondary, supplies power to controller only.

The Power light will be ON when the transformer

has provided 12 volts AC to the controller.

Water Level Sensor
• Two probe conductivity sensor. When water touches

it the Water Present light will be ON.

Auger Motor
• Four pole, split phase motor that operates the gear

reducer. When operating, the Auger indicator light

will be ON. The gear reducer lowers the input speed

from about 1500 RPM to 11. Auger rotation is CCW

when viewed from above.

Photo-electric eyes
• An LED emitter and photo transistor receiver set.

Pulsed infrared light is continuously emitted and

received to detect ice in the chute.

Lower light and switch panel
• Used only on Prodigy Plus D series. Duplicates

controller lights and switches.