N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522
Air, Water or Remote Service Manual

December 2014

Page 41

Symptom

Probable Cause

Possible Correction

No ice

No power

If power light is out and there

is power to the unit, check

transformer.

Code 3: No water

Restore water, check filters, water

level and sensor

Status light is off

Push and release ON switch

Code 1: No ice sensed

Check for ice flow down chute. if

very slow or no ice being made,

check for refrigeration system

failure
Check auger motor for power, if no

power, check controller component

indicator light. If there is power to

the motor, check motor windings

Code 2: Auger motor draws too

many amps, controller shut unit off.

Check for damage to gear reducer

or auger bearings.

Bin Eyes Blocked light is On

Ice is in the chute.
No ice in the chute. Check position

of sensors, check sensors for scale

build up

Code 4: Refrigeration system over

or under pressure

Check water flow to condenser;

check for proper flow of water

into evaporator; check refrigerant

charge

Code 4: Chute thermostat opened Unit overfilled, check photo eye

system

Everything is in operation, but no

refrigeration effect

Check water regulating valve
Check TXV superheat
Check refrigerant charge

Optional bin thermostat is open

Check thermostat or jumper wire

on blue wires to #5 & #6

Optional ultrasonic system set too

low

Adjust selector switch to a higher

position

Optional ultrasonic system senses

false bin full

Check sensor for proper

installation and operation

Low ice making capacity

Scale build up

Remove scale from evaporator and

water system

Restricted water to evaporator

Check for air bubble in hose,

change reservoir if found

High discharge pressure

Check water regulating valve

Expansion valve superheat

incorrect

Check superheat

Service Diagnosis - Water Cooled