N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522
Air, Water or Remote Service Manual

December 2014

Page 34

Refrigeration System Pressures

Refrigeration system pressures of continuous flow ice machines do not vary a great deal while in operation.

They will vary by model, condenser type and ambient.

70/50

90/70

Model

Suction (PSIG)

Discharge (PSIG)

Suction (PSIG)

Discharge (PSIG)

N0422A

37-39

235-245

45-46

255-265

N0422W

38-40

240-250

38-42

240-250

F0522A

37-39

235-245

40-42

250-260

F0522W

37-39

240-250

39-41

240-250

N0622A

28-31

235-245

35-40

275-285

N0622W

29-32

240-250

30-34

240-250

N0622R

35-37

240-250

36-38

250-260

F0822A

28-31

235-245

34-39

285-295

F0822W

29-32

240-250

30-34

240-250

F0822R

35-37

240-250

36-38

250-260

N0922A

22-25

205-215

32-33

280-290

N0922W

22-25

240-250

31-33

240-250

N0922R

28-30

240-250

31-32

245-255

F1222A

22-25

205-215

31-33

280-290

F1222W

22-25

240-250

30-33

240-250

F1222R

28-30

240-250

31-32

245-255

N1322A

22-25

205-215

30-32

295-305

N1322W

26-28

240-250

25-28

240-250

N1322R

29-30

230-240

30-31

245-255

F1522A

22-25

205-215

28-32

295-305

F1522W

26-28

240-250

25-28

240-25