beautypg.com

Scotsman Prodigy Plus D Series Service Manual User Manual

Page 11

background image

N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522
Air, Water or Remote Service Manual

December 2014

Page 11

The water supply for ice making must be cold, potable

water. There is a single 3/8” male flare potable water

connection on the back panel. Water cooled models

also have a 3/8” FPT inlet connection for the water

cooled condenser. Chilled water can also be used for

this connection.

Drain

There is one ¾” FPT condensate drain fitting at the

back of the cabinet. Water cooled models also have a

½” FPT discharge drain connection on the back panel.

Tubing

Connect the potable water supply to the potable water

fitting, 3/8” OD copper tubing or the equivalent is

recommended.

Water filtration is recommended. If there is an existing

filter, change the cartridge.

Connect the water cooled water supply to the

condenser inlet.

Note: Do NOT filter water to the water cooled

condenser circuit.

Connect the drain tube to the condensate drain fitting.

Connect the water cooled condenser drain tube to the

condenser outlet.

Do not Tee ice machine drains into the drain tube

from the ice storage bin or dispenser. Back ups

could contaminate and / or melt the ice in the bin or

dispenser.

Follow all local and national codes for tubing, traps

and air gaps.

Water

Water Inlet

Connection

Drain

Connection

Condensate

Drain Tube

Building Drain

Water Inlet

Connection

Drain

Connection

Condensate

Drain Tube

Condenser Inlet

Connection

Condenser

Drain Tube

Air Cooled or Remote Plumbing

Water Cooled Plumbing