N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522
Air, Water or Remote Service Manual

December 2014

Page 40

Service Diagnosis - Air Cooled

Symptom

Probable Cause

Possible Correction

No ice

No power

Check that ice machine has

power. If power light is out, check

transformer.

Code 3: No water

Restore water, check filters, water

level and sensor

Status light is off

Push and release ON switch

Code 1: No ice sensed

Check for ice flow down chute. if

very slow or no ice being made,

check for refrig. system failure
Check auger motor for power, if no

power, check controller component

indicator light. If there is power to

the motor, check motor windings

Code 2: Auger motor draws too

many amps, controller shut unit off.

Check for damage to gear reducer

or auger bearings.
Check for restriction between

reservoir and evaporator

Bin Eyes Blocked light is On

Ice is in the chute.
No ice in the chute. Check position

of sensors, check sensors for scale

build up

Code 4: Refrigeration system over

or under pressure

Check for proper operation of the

fan and motor; check for proper

flow of water into evaporator;

check for proper refrigerant charge

Code 4: Chute thermostat opened Unit overfilled chute, check photo

eye system

Everything is in operation, but no

refrigeration effect

Check compressor
Check TXV superheat
Check refrigerant charge

Optional bin thermostat is open

Check thermostat or jumper wire

on blue wires to #5 & #6

Optional ultrasonic system senses

false bin full

Check sensor for proper

installation and operation

Low ice making capacity

Scale build up

Remove scale from evaporator and

water system

Air filter dirty

Clean air filter

Condenser fins dirty

Clean condenser

Restricted water to evaporator

Check for air bubble in hose,

change reservoir if found

Expansion valve superheat

incorrect

Check superheat