N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522
Air, Water or Remote Service Manual

December 2014

Page 18

Water - Remote Models

The water supply for ice making must be cold, potable

water. There is a single 3 8” male flare potable water

connection on the back panel.

Backflow

The design of the float valve and reservoir prevents

potable water backflow by means of a 1" air gap

between the reservoir's maximum water level and the

float valve water inlet orifice.

Drain

There is one ¾” FPT condensate drain fitting at the

back of the cabinet.

Attach Tubing

1. Connect the potable water supply to the potable

water fitting, 3 / 8” OD copper tubing or the

equivalent is recommended.

2. Change the cartridge on the existing water filter (if

any present).

3. Connect the drain tube to

the condensate drain fitting.

Use rigid tubing.

4. Vent the drain tubing

between the ice machine

and the building drain.

Do not Tee ice machine drains into the drain tube

from the ice storage bin or dispenser. Back ups

could contaminate and / or melt the ice in the bin or

dispenser. Be sure to vent the bin drain.

Follow all local and national codes for tubing, traps

and air gaps.

To Remote Condenser

Potable Water

Connection

Drain Vent