Scotsman Prodigy Plus D Series Service Manual User Manual
Page 27
![background image](https://www.manualsdir.com/files/803915/content/doc027.png)
N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522
Air, Water or Remote Service Manual
December 2014
Page 27
Water System
Water enters the machine through the 3/8" male flare
at the rear of the cabinet, goes to the water reservoir
which it enters through the float valve.
The float valve maintains a constant level of water in
the reservoir and evaporator, as water flows out the
bottom of the reservoir tank to fill the evaporator.
Reservoir overflow or evaporator condensation is
routed to the drain. Water cooled models have a
separate water circuit for the cooling water: it nters the
fitting at the rear, goes to the water regulating valve,
then to the water cooled condenser and down the
drain.
Water Level: The correct water level should be
checked when the machine is making ice. Check
the water level in the reservoir and compare it to the
horizontal line molded into the side of the reservoir.
The correct level should be between 1/8” above and
1/4” below the line. If needed, bend the float arm up
or down to adjust the water level.
Note: Water sensor moved to reservoir in 2012, water
inlet hose and reservoir revised in 2013 and 2014.
Water Level
Float Valve
Water Sensor
Water Inlet to Evaporator
Condensate
Pan
Water System Schematic