beautypg.com

Scotsman Prodigy Plus D Series Service Manual User Manual

Page 27

background image

N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522
Air, Water or Remote Service Manual

December 2014

Page 27

Water System

Water enters the machine through the 3/8" male flare

at the rear of the cabinet, goes to the water reservoir

which it enters through the float valve.

The float valve maintains a constant level of water in

the reservoir and evaporator, as water flows out the

bottom of the reservoir tank to fill the evaporator.

Reservoir overflow or evaporator condensation is

routed to the drain. Water cooled models have a

separate water circuit for the cooling water: it nters the

fitting at the rear, goes to the water regulating valve,

then to the water cooled condenser and down the

drain.

Water Level: The correct water level should be

checked when the machine is making ice. Check

the water level in the reservoir and compare it to the

horizontal line molded into the side of the reservoir.

The correct level should be between 1/8” above and

1/4” below the line. If needed, bend the float arm up

or down to adjust the water level.

Note: Water sensor moved to reservoir in 2012, water

inlet hose and reservoir revised in 2013 and 2014.

Water Level

Float Valve

Water Sensor

Water Inlet to Evaporator

Condensate

Pan

Water System Schematic