Service Diagnosis - Remote Air Cooled

Symptom

Probable Cause

Possible Correction

No ice

No power

If ice machine has power

and power light is out, check

transformer.

Code 3: No water

Restore water, check filters, water

level and sensor

Status light is off

Push and release ON switch

Code 1: No ice sensed

Check for ice flow down chute. if

very slow or no ice being made,

check for refrigeration system

failure
Auger motor working, compressor

off. Check liquid line valve and

pump down switch
Check auger motor for power, if no

power, check controller component

indicator light. If there is power to

the motor, check motor windings or

start switch

Code 2: Auger motor draws too

many amps, controller shuts unit

off.

Check liquid line valve for leak

through, causing auger to freeze in

place
Check for damage to gear reducer

or auger bearings.

Bin Eyes Blocked light is On

Ice is in the chute.
No ice in the chute. Check position

of sensors, check sensors for scale

build up

Code 4: High discharge pressure

Check remote condenser fan

motor

Code 4: Chute thermostat opened Unit overfilled, check photo eyes
Everything is in operation, but no

refrigeration effect

Check liquid line valve
Check compressor
Check TXV superheat
Check refrigerant charge

Optional ultrasonic system set too

low

Adjust selector switch to a higher

position

Optional bin thermostat is open

Check thermostat or jumper wire

on blue wires to #5 & #6

Optional ultrasonic system senses

false bin full

Check sensor for proper

installation and operation