beautypg.com

Scotsman Prodigy Plus D Series Service Manual User Manual

Page 12

background image

N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522
Air, Water or Remote Service Manual

December 2014

Page 12

The machine does not include a power cord, one

must be field supplied or the machine hard wired to

the electrical power supply. The junction box for the

electrical connection is on the back panel.

Refer to the dataplate on the machine for minimum

circuit ampacity and determine the proper wire size

for the application. The dataplate (on the back of the

cabinet) also includes the maximum fuse size.

Electrical

Electrical power is connected to wires inside the

junction box in the back of the cabinet. Use a strain

relief and connect a ground wire to the ground screw.

Do not use an extension cord.

Follow all local and national codes.

Model

Series

Dimensions

w" x d" x h"

Voltage

Volts/Hz/

Phase

Condenser

Type

Min Circ

Ampacity

Max Fuse

Size or HACR

Type Circuit

Breaker

N0422A or F0522A-1

A or D

22 x 24 x 23 115/60/1

Air

15.2

20

N0422W or F0522W-1

A or D

same

115/60/1

Water

14.4

20

N0622A or F0822A-1

A or B or D

same

115/60/1

Air

18.3

25

N0622W or F0822W-1

A or B or D

same

115/60/1

Water

16.7

25

N0622R or F0822R -1

A or B or D

same

115/60/1

Remote

19.4

25

N0622A or F0822A-32

A or B

same

208-230/60/1 Air

9.8

15

N0622W or F0822W-32

A or B or D

same

208-230/60/1 Water

8.9

15

N0922A or F1222A-32

A

22 x 24 x 27 208-230/60/1 Air

12.5

15

N0922W or F1222W-32

A

same

208-230/60/1 Water

11.3

15

N0922R or F1222R -32

A

same

208-230/60/1 Remote

12.3

15

N0922A or F1222A -3

A

same

208-230/60/3 Air

13.0

15

N0922R pr F1222R -3

A

same

208-230/60/3 Remote

12.8

15

N0922A or F1222A-32

B or D

same

208-230/60/1 Air

13.2

20

N0922W or F1222W-32

B

same

208-230/60/1 Water

12

15

N0922R or F1222R -32

B or D

same

208-230/60/1 Remote

13

20

F1222A-3

B or D

same

208-230/60/3 Air

10.5

15

F1222R-3

B or D

same

208-230/60/3 Remote

10.3

15

N1322A or F1522A -32

A or D

same

208-230/60/1 Air

19.1

30

N1322W or F1522W -32 A or D

same

208-230/60/1 Water

17.9

30

N1322R or F1522R -32

A or D

same

208-230/60/1 Remote

18.9

30

N1322W

A or D

same

208-230/60-3 Water

11.15

15

This manual is related to the following products: