N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522
Air, Water or Remote Service Manual

December 2014

Page 24

Refrigeration

Refrigerant: R-404A
Compressors: Copeland or Tecumseh hermetic by

model

Expansion valve: Adjustable, internally equalized.
Condensers: Air is forced draft type, water cooled is

counterflow type.

Air filters: Surface mounted to panels. Filter media

removable without removing panels.

Fan blades: Reduced vibration blades in most air

cooled models.

Remote Systems: Head pressure control valve in

condenser. Headmaster protected by filters (not

filter driers). Controller pumps unit down by closing

the liquid line valve. Pump down switch controls the

compressor.

High pressure cut out. WC, RC, AC

Low pressure cut out, WC, AC

Pump down pressure switch, RC

Evaporator: Coil-wrapped stainless steel with a

stainless steel, double-flight auger inside.

Initial Start Up
1. Turn the water supply on.

2. Switch the electrical power on. Confirm voltage is

correct for the model.

3. Push and release the On button. The machine will

start in about two minutes.

4. Soon after starting, air cooled models will begin

to blow warm air out the back of the cabinet and

water cooled models will drain warm water from

the condenser drain tube. Remote models will be

discharging warm air from the remote condenser.

After about 5 minutes, ice will begin to drop into the

bin or dispenser.

5. Check the machine for unusual rattles. Tighten any

loose screws, be sure no wires are rubbing moving

parts. Check for tubes that rub.

6. Fill out the warranty registration form and either file

it on line or mail it.

7. Notify the user of the maintenance requirements

and whom to call for service.

Change De-Scale Notification Interval

This feature is accessible only from standby

(Status Light Off).

1. Press and hold Clean button for 3 seconds. This starts the Time to Clean Adjustment State and displays

the current time to clean setting.

2. Press the clean button repeatedly to cycle through the 4 possible settings:

• 1 year (8760 hours)

• 0 (disabled)

• 4 months (2920 hrs)

• 6 months (4380 hours) (default)

3. Push Off to confirm the selection.