4. Menu Orientation

MENU

VENUS X1 User Manual 47

BIT DEPTH: Can set the image bit depth. DVI default 8 bit, user don’t need

to set it. HDMI default 10 bit, and can choose 8 bit or 12 bit.

DATE RANGE: DVI1 output range, can set as RGB (graphic mode or

YCbCr (video mode), RGB output scale range from 0 to 255, YCbCr

range from 16 to 235.

DE ADJUST: DE adjust, sub menu as following:

DE ON/OFF: Can choose to open or close, when choose open, it can be

adjusted to DE, as follows:

H SIZE: Width setting.

V SIZE: Height setting.

H POS: Horizontal phase setting.

V POS: Vertical phase setting.

When the signal source of the screen appear black side, can use this

function to shift the black out of the screen.

RESET: If image quality distorts by improper operation, it can be recover by

reset.

ASPECT RATIO: Aspect ratio setting, user can choose 4:3, 16:9 and

DEFAULT.

PICTURE

Push the [MENU] button to go into the menu items, turn the knob button to

select , show menus as follows:

IMAGE QUALITY: Image quality setting, the sub-menu as following:

BRIGHTNESS: It can change the image brightness via BRIGHTNESS

setting.

CONTRAST: It can change the image contrast via CONTRAST setting.

SATURATION: It can change the image saturation via SATURATION

setting.