33

SYSTEM INITIALIZE

SYSTEM INITIALIZE
------------------------
CLEAR ALL DATA NO
CLR DISPLAY SET NO
CLR CAMERA SET NO
CLR MOTION SET NO
CLR EDIT DATA NO
REBOOT CAMERA NO
REBOOT SYSTEM NO

BACK
EXIT

Clear All Data

Deletes all configuration data such as display, camera,
motion setup and so on.

Clear Display Set

Initializes Display Configuration

Clear Camera Set

Initializes Camera Configuration

Clear Motion Set

Initializes Motion Configuration

Clear Edit Data

Deletes Preset Data, Swing Data, Pattern Data and Group
Data

Reboot Camera

Reboots Zoom Camera module

Reboot System

Reboots Speed Dome Camera

INITIAL CONFIGURATION TABLE

Display Configuration

Camera Configuration

Camera ID

ON

Focus Mode

SemiAuto

PTZ Information

AUTO

Digital Zoom

ON

Action Title

AUTO

Line Lock

OFF

Preset Label

AUTO

White Balance

AUTO

Alarm Input

AUTO

Backlight

OFF

North Direction

Pan 0

°

Day&Night AUTO1

Privacy Zone

Undefined

Brightness

25

Iris

AUTO

Shutter

ESC

Motion Configuration

AGC NORMAL

Motion Lock

OFF

SSNR

MIDDLE

Power Up Action

ON

SENS-UP

AUTO (4 Frame)

Auto Flip

ON

Jog Max Speed

120

°/sec

User Edit Data

Jog Direction

INVERSE

Preset 1~128

Undefined

Freeze In Preset

OFF

Swing 1~8

Undefined

Park Action

OFF

Pattern 1~4

Undefined

Alarm Action

OFF

Group 1~8

Undefined