Cabling, Power connection, Grounding – OpenEye CM-410 User Manual
Page 21: Power wire length specifications

28561AA
11
CABLING
Cabling Terminal Block
Power
Controller/ DVR
BNC
Monitor
IrDA
Sensor
Door
Switch
Sensor
POWER CONNECTION
• Check the voltage and current capacity of rated power carefully. Rated power is indicated on the back of the main unit.
Rated Power
Input Voltage Range
Current Consumption
AC 24V
AC 17V ~ 29V
0.4 A
Grounding
The GND (ground) wire must be directly connected to the F.G. pin of the cabling terminal block. Failure to connect the ground can
cause damage and failure of the camera and may void the warranty.
If the connection of the GND wire causes video noise, use a video isolator. This is only necessary in some situations.
Power Wire Length Specifications
Wire Gauge
Maximum Distance
22
178
feet
20
284
feet
18
451
feet
16
716
feet
14
1138
feet
12
1811
feet
10
2886
feet