22 electrical, Electrical – Nortec SE Series User Manual
Page 25
Installation | 22
Electrical
Figure 19: Primary Power Connection
Caution:
Wiring to be performed by a licensed Electrician.
All SE humidifiers operate on 120 VAC, single phase, 60 HZ power. Refer to
specification label for power requirements.
L1
Neutral
Ground
L1
Neutral
Ground
SETC / P Primary Power
Single Phase Supply
Note:
1
2
3
Dedicated external fused
disconnect must be installed.
Fusing must not exceed max
circuit protection as indicated
on the specification label.
Ensure that adequate power is
available to carry full humidifier
amp draw as indicated on the
specification label.
All wiring to be in accordance
with national and local electrical
codes.
E
X
T
I
N
T
High voltage
terminal block
Knockouts provided
in top and bottom panels.
Install strain relief (by others)
Dedicated circuit
breaker or fused
disconect.