* Currently the DM software does not support the new GCF format for
higher sample rates. It also does not properly support 250 samples/s,
nor rates below 1 sample/s.
CONTINUOUS
Syntax: tap components CONTINUOUS
Sets which components are output under normal conditions, and at
which tap(s).
tap is the tap number at which to output the triggered stream. You
can set which taps output which sample rate using the SAMPLES/SEC
command, described above.
components is an integer below 16, whose binary bits represent the
Z (1), N (2), E (4) and auxiliary (8) components respectively. Thus, for
example:
•
0 1 CONTINUOUS will output the Z component only (1) at the
first tap;
•
0 2 CONTINUOUS will output the N component only (2);
•
0 4 CONTINUOUS will output the E component only (4);
•
0 7 CONTINUOUS will output all three directional components
(1 + 2 + 4 = 7);
•
0 12 CONTINUOUS will output the E component and the
auxiliary component (4 + 8 = 12);
•
0 0 CONTINUOUS will output nothing at the first tap.
SET-TAPS
Syntax: tap-0 tap-1 tap-2 tap-3 SET-TAPS
This is an alternative to the CONTINUOUS command, which allows you
to set the outputs for all taps simultaneously.
tap-0 to tap-3 are integers below 16, whose binary bits represent the
Z (1), N (2), E (4) and auxiliary (8) components respectively. Each one
sets which components are output at that tap under normal
conditions.
62
Issue N