Error:
Column and HCU don’t operate in cable mode.

Solution:

Check if

o

the emergency OFF Switch is inserted into the off position. If so, twist

clockwise to deactivate.

o

the cable is connected correctly.

o

the connectors are damaged (broken or bent pin).

o

the same problem occurs with a different cable.

o

the battery poles on the column are extended and not flush with column.

o

the batteries are charged.



Error:
The column cannot be calibrated.

Solution:

Check if

o

the correct button combination is being pressed to activate the calibration mode
(see „4.2 “calibrating the column” on 10).

o

the emergency OFF Switch is inserted into the off position. If so, twist clockwise
to deactivate.

o

the batteries are charged.


Check the operational mode!

Wireless mode:
Check if
o

the electronic is switched on. In wireless mode it must be switched on first.

o

the HCU is equipped for wireless operation and not that it’s only equipped for
cable operation.

o

the HCU battery is in place. The wireless mode does not work without battery.

o

both the HCU and electronic were synchronized (see „4.1 Synchronizing the
HCU and Column on page 8 )and that they are sending and receiving on the
same channel.

If the above solutions do not result in an improvement change to cable mode and repeat the calibration
procedure

.


Cable mode:
Check if
o

the cable is connected correctly.

o

the connectors are damaged (broken or bent pin).

o

the same problem occurs with a different cable.




Error:
The calibration mode disrupts by itself during the procedure:

Solution:
Change from cable to wireless mode or vice versa, then try again.