Page: 35
In emergency mode, if the column needs to be moved
§ upwards, insert the plug in the middle connector.
§ downwards, insert the plug in the lower connector.
Attention:
When inserting the plug do not clamp or jam any cables!
Note:
The plug has an anti-twist protection and inserts in one direction only.
Press the hidden emergency button found in the round hole at the bottom of the 3
connectors. The column will move in the respective direction according to where the
plug is positioned.
Attention:
When replacing the cover ensure that the emergency plug is inserted into the top
connector as the cover cannot be mounted if the plug is in another position.
Plug for upward emergency mode
Plug for downward emergency mode