GF-Primo / GF-Secondo Dolly System Instruction Manual

Page: 39

Error:
It’s not possible to switch on the electronic / column.

Solution:
Is the emergency OFF Switch inserted into the off position? If so, twist clockwise to
deactivate.

Check that the batteries are charged and connected correctly to the column.

Remove the batteries from the column and check the battery poles on the column. They
should be sticking out from the connection plate and not flush with it. Reconnect the
batteries and check the connection. The top of the battery housing should be flush with the
column.

If the electronic was removed, double check to make sure it is connected correctly. The
electronic housing must be flush with the connection plate on the column.
Concerning operational mode:

Wireless mode:
Press the on switch on the electronic for approx. 5 seconds.

In wireless mode always activate the electronic, then the HCU.
In wireless mode the HCU and electronic must have been synchronized prior
to use. Synchronization must take place when the HCU is exchanged or
replaced. (see „4.1 Synchronizing the HCU and Column on page 8)

Cable mode:

The column can be switched on directly with the HCU.


Error:
The HCU cannot be switched on or keeps switching itself off (although the electronic is
switched on):

Solution:
Check the operational mode!

In wireless mode:
Check if

o

the electronic is switched on. In wireless mode it must be switched on first.

o

the emergency OFF Switch is inserted into the off position. If so, twist clockwise
to deactivate.

o

the HCU is equipped for wireless operation and not that it’s only equipped for
cable operation.

o

the HCU battery is in place. The wireless mode does not work without battery.

o

both the HCU and electronic are sending and receiving on the same channel.


Before operating the column and the HCU for the first time it is necessary to synchronize
both units.


Cable mode:
Check if

o

the emergency OFF Switch is inserted into the off position. If so, twist

clockwise to deactivate.

o

the cable is connected correctly.

o

the connectors are damaged (broken or bent pin).

o

the same problem occurs with a different cable.