Calibrating the column, Calibration procedure – Grip Factory Munich GF-Primo User Manual
Page 38

GF-Primo / GF-Secondo Dolly System Instruction Manual
Page: 37
Calibrating the column
The column will need to be calibrated :
o
After a service or repair
o
After a software update
o
After the column is crashed / driven against an object / hit the mechanical top or bottom of
column lift range
o
After using emergency switch
Calibration procedure
Press and hold the SPD-button, then switch the column / HCU on. As soon as the HCU LED is on
the SPD-button can be released.
The Display shows „CAL DOLLY CONTROL“.
Press the CAL button (RMP) button to begin.
The column will automatically drive to its lowest position and then to the maximum height. Upon
reaching the maximum height press EXIT.
Press SPD and On.
Then press CAL to
begin