Trouble Shooting

The following describes some possible errors and the solutions to correct the errors.

Error:
Dolly and HCU are not functioning in wireless mode

Solution:
Check

o

Are the HCU and column equipped with wireless modules?

o

Is the emergency OFF Switch inserted into the off position? If so, twist clockwise
to deactivate.

o

If the HCU battery is in place. The wireless mode does not work without battery.

o

Are the HCU and electronic synchronized? If not, connect via the HCU cable.

o

Are both the HCU and electronic sending and receiving on the same channel?


Error:
In wireless mode there is a disturbance in the movement of the column.

Solution:
Select the next or any other channel e.g. 4.
If this doesn’t help, change to cable operation.

Check the battery voltage with a loaded column. Should the voltage fall below 19V replace
or charge the batteries.

Check the motor temperature. In general terms the following can be said about the electro-
motor:

The hotter the motor becomes, the higher the performance loss. Should the motor reach a temperature of
60°C the column will shut down automatically to avoid permanent damage. However, it is suggested to avoid
use of the column when the temperature exceeds 50°C.

If the above solutions do not result in an improvement of the columns performance please service the
column (see “servicing the column”).



Error:
Disturbance of movement during cable operation.

Solution:
Check the battery voltage with a loaded column whilst moving up and down. Should the
voltage fall below 19V replace or charge the batteries.

Check the motor temperature. In general terms the following can be said about the electro-
motor:

The hotter the motor becomes, the higher the performance loss. Should the motor reach a temperature of
60°C the column will shut down automatically to avoid permanent damage. However, it is suggested to avoid
use of the column when the temperature exceeds 50°C.