Gasboy FuelOmat Payment Terminal User Manual
Page 67
OrPT Manual
57
1. Enter the new RS-485 address, which should match the address specified in the Station
Controller setup. The address shall be entered in a decimal number, up to three digits, not in
a Hex number.
N
N
O
O
T
T
E
E
The RS-485 link refers to the OrPT by its Hex
address. However, at definition, the decimal value
shall be entered.
2. Press the keyboard numeral keys to enter the address.
W R I T E A D R . 4 8 5
_ _ _
S N : 1 9 0 0 7 0 7 2 6 4 6 0 0 5
Figure 5-4. RS-485 Address Input Screen
3. Press OK key. The current application screen, as defined by the Station Controller in the
SiteOmat is displayed, see example below.
5-3.4. OrPT Functional Screen - Example
Figure 5-5 shows a typical example of a functional screen in the OrPT front panel. This particular
screen enables to determine the amount of fuel to be supplied to a driver that has presented his
contact-less key to the tag reader in the OrPT front panel. The following procedure is an example
of an interactive procedure between the driver and the OrPT.
N
N
O
O
T
T
E
E
This scenario depends on the definitions made in the
System Controller, and may consequently vary from
one application to another.
W e l c o m e
- - > P r e s e n t
T a g
- - > S w i p e C a r d
F 2 - R C P T
Figure 5-5. Fuel Limit Input Screen