beautypg.com

Gasboy FuelOmat Payment Terminal User Manual

Page 28

background image

OrPT

Manual

18

2-10.2. Installation Requirements

z

Install the OrPT at the non-hazardous area.

When the OrPT is installed in Islander Plus pedestal, it is inherently considered a non-
hazardous area if the Islander Plus had been installed according to safety requirements (refer
to Gasboy's Document No. MDE - 4811)

z

Installation must be conducted by a technician authorized to work in a flammable gas
station environment in accordance with the local requirements and regulations.

z

Certify that the required installation preparations have been made:

-

Power supply to the OrPT

-

Installation location

2-10.3. Installation Kit

The items in the installation kit for an OrPT are listed in Table 2-5.

Table 2-5. OrPT Installation Kit

P/N Description Function

Qty.

814942700 CLAMP

HOUSING,

OrPT

PANEL

Mounting

1

815200104

SCREW WING M4x10, BOSSARD

Mounting

2

2-10.4. Installation Procedure

The OrPT is provided with its holder attached to it.

Perform the following procedure to install the OrPT unit onto the Islander Plus:

a. Disconnect all power sources in installation area, including power source to Gasboy

pedestal.

W

W

A

A

R

R

N

N

I

I

N

N

G

G

Conform to all safety regulations regarding working
in gas stations.

b. The OrPT is fed by 24Vdc. Use a stabilized power directly from the Orpak pedestal.

c. Connect all cable plugs to their mating connectors on the OrPT connectors panel, in

accordance with paragraph 2-5 on page 12.