Fuel Truck Controller Manual

74

All pumps are

showing

"warning" signs

on the SiteOmat

Status screen

Incorrect 8-port

CommVerter setup

Check network

connectivity by

performing a "ping"

command locally or

remotely, through

PuTTY application

2. Check the status of the

LEDs on the 8-port (upper

right corner of the board):

the first and the third LED

should be lit to confirm

power and network

connection, while second

LED should blink to confirm

network activity. The last

two LEDs (from left to

right) should be blinking

constantly, to confirm

communication with

controller

3. In cases where all LEDs are

lit periodically (every 30

seconds) the unit is resetting

due to connection loss to the

controller

4. Reset the IP and reconfigure

the Pump Server (PS) in

controller setup

No communication to nozzles (Wireless Gateway)

Can’t read the

vehicles and/or

no authorization

at the pumps

1. No

communication

to Wireless

Gateway

2. Incorrect nozzle

readers setup

Check the physical

connection of the

Wireless Gateway to

the local network (5-

port switch)
Check the Wireless

Gateway network

settings

1. If no activity on the LAN

port, check the cable and/or

change the port on the 5-port

switch

2. Remove the top cover to

access the Wireless Gateway

and check the status of the

LEDs



Table 4-2. Communication Troubleshooting (Cont'd)

Fault

Probable Cause

Checks

Corrective Action

No communication to nozzles (Wireless Gateway) (Continued)