Gasboy Fuel Truck Controller User Manual
Page 67

Fuel Truck Controller Manual
61
4
4
-
-
5
5
.
.
P
P
R
R
I
I
N
N
T
T
E
E
R
R
S
S
E
E
T
T
U
U
P
P
NOTE
Mobile Printer is set through SiteOmat. For further
details, please refer to SiteOmat Installation and
Maintenance Manual
P/N MDE-4817.
In order to set up the Fuel Truck Controller Mobile Printer, proceed as follows:
1. Connect the technician PC to any free connector on the 5 port switch with an Ethernet
cable (CAT5E)
2. Browse to the default IP address of the OrCU Administrator screen:
3. At the Login dialog box, enter the User name (Default: admin) and Password (Default:
admin) and click OK. The OrCU Administrator Home screen appears
4. Click on the Serial/Modem navigation button. The OrCU Serial/Modem Settings screen
appears (see Figure 4-3)
Figure 4-3. OrCUAdministrator – Serial/Modem Settings Screen
5. Select the Use port for External Devices (TLG) (Com2) radio button
6. Click on Set Serial/Modem settings to save the changes
7. Click on the System Information navigation button. The following screen appears