Fuel Truck Controller Manual

67

System is down

No

communication
OrCU LEDs are

not lit

Fuel Truck

Controller main

switch or truck’s

ignition switch are

off

Turn main switch/ truck’s

ignition switch on.
After power on, wait a few

seconds for the Timer

Relay to be connected

Defective fuses

Check the fuses
1. External fuse (6 Amp)
2. Internal fuse harness

(Orpak P/N

180831918) which is

located between the

Terminal block (TB

43) the and Line Filter

Replace the fuses if blown

No 12 VDC/24

VDC feed to the

unit

Verify all input power

connections :
1. Check cabling from

Junction Box to the

unit

2. Verify that power

cable is properly

connected to unit

terminal block

3. Verify the Input &

Output voltage of the

DC2DC Converter

4. Is 12 VDC/24VDC

measured at the power

input terminal block?

Correct wiring problems if

12VDC/24VDC is not

measured




Table 4-1. Fuel Truck Controller Troubleshooting (Cont'd)

Fault

Probable Cause

Checks

Corrective Action

System is down (Continued)