beautypg.com

Table ‎2-2. fuel truck controller, cables type – Gasboy Fuel Truck Controller User Manual

Page 38

background image

Fuel Truck Controller Manual

32

NOTE

The type of required cable varies in accordance with

the device it connects. The wire used must be

stranded and not a solid core. Select a cable

specification in accordance with local environment

conditions.

CAUTION

For supply connections, use wires suitable for at

least 90°C.
Signal wiring connected in this box must be rated at

least 300 V

2

2

-

-

4

4

.

.

2

2

.

.

C

C

a

a

b

b

l

l

e

e

T

T

y

y

p

p

e

e

s

s

Table ‎2-2 lists the types of cables used for the wiring of the Fuel Truck Controller system.

Table ‎2-2. Fuel Truck Controller, Cables Type

No.

Function

Type

1

Power supply and valve control As used in vehicles 1.5 – 2.5 mm²

(15 to 13 AWG)

2

Coil (Barrier)

Data communication cable, 300 V RMS,

90ºC, shielded twisted pair, oil

resistant, 24 AWG, low capacitance

below 60 PF/meter similar to Belden

9729 cable

3

Pulser and In-use signal

4

LAN

CAT5E, Shielded , 300 V RMS, 90ºC

similar to Belden 121700A

5

GND

Ground cable 0.4" (10.8 mm

2

)

Connections should be done through a junction box (4x4x4" (10x10x10 cm)) located near

peripherals.

2

2

-

-

4

4

.

.

3

3

.

.

C

C

a

a

b

b

l

l

e

e

s

s

R

R

o

o

u

u

t

t

i

i

n

n

g

g

Route the cables from peripherals to Fuel Truck Controller as listed in Table ‎2-3 and Table ‎2-4.

Proceed as follows: