Table 2-2. fuel truck controller, cables type – Gasboy Fuel Truck Controller User Manual
Page 38

Fuel Truck Controller Manual
32
NOTE
The type of required cable varies in accordance with
the device it connects. The wire used must be
stranded and not a solid core. Select a cable
specification in accordance with local environment
conditions.
CAUTION
For supply connections, use wires suitable for at
least 90°C.
Signal wiring connected in this box must be rated at
least 300 V
2
2
-
-
4
4
.
.
2
2
.
.
C
C
a
a
b
b
l
l
e
e
T
T
y
y
p
p
e
e
s
s
Table 2-2 lists the types of cables used for the wiring of the Fuel Truck Controller system.
Table 2-2. Fuel Truck Controller, Cables Type
No.
Function
Type
1
Power supply and valve control As used in vehicles 1.5 – 2.5 mm²
(15 to 13 AWG)
2
Coil (Barrier)
Data communication cable, 300 V RMS,
90ºC, shielded twisted pair, oil
resistant, 24 AWG, low capacitance
below 60 PF/meter similar to Belden
9729 cable
3
Pulser and In-use signal
4
LAN
CAT5E, Shielded , 300 V RMS, 90ºC
similar to Belden 121700A
5
GND
Ground cable 0.4" (10.8 mm
2
)
Connections should be done through a junction box (4x4x4" (10x10x10 cm)) located near
peripherals.
2
2
-
-
4
4
.
.
3
3
.
.
C
C
a
a
b
b
l
l
e
e
s
s
R
R
o
o
u
u
t
t
i
i
n
n
g
g
Route the cables from peripherals to Fuel Truck Controller as listed in Table 2-3 and Table 2-4.
Proceed as follows: