4 data monitor, Data monitor commands, Command: h – Gasboy Gilbarco Interface Unit User Manual
Page 43: Command: w, Data monitor
![background image](https://www.manualsdir.com/files/787407/content/doc043.png)
Gilbarco Interface Unit v2.1
Data monitor
35
Gasboy CFN Series
4
Data monitor
Once all connections have been made and all switches set correctly, the system still does not
always function correctly. As an aid to diagnosing remaining problems, the interface unit is
equipped with a data monitor program.
The monitor program is accessed by connecting a terminal to the local port. The baud rate
must agree with the rate switched in on interface unit switches DIP switch bank 3, positions 1
and 2.
The data monitor command m or just ENTER is used to determine whether communication
has been established.
Data monitor commands
The monitor commands are discussed below:
Monitor Commands
Key
Modifier
Effect
h
—
Show list of commands and status
w
—
Show monitor status
m
—
Monitor next data port
p
—
Monitor pump data port
c
—
Monitor CRIND data port
g
—
Monitor GSM data port
s
Monitor all devices on port
s
0-f
Monitor only one device
n
—
Toggle display all/new messages
—
Halt or restart display
?
—
Display device status and counters
*
—
Reset counters
r
—
Toggle display raw/cooked mode
Command: h
Print help menu. The commands are listed, with a brief explanation of each. The
key also
elicits this.
Command: w
Print status. The monitor shows its print mode (off or on), whether it is printing all messages or
just new ones (verbose or terse), which data port it is watching (line 1 or line 2), and what device
or devices it is watching.
ENTER