Prepare pump.bin data – Gasboy Gilbarco Interface Unit User Manual
Page 26

18
Installation
Gilbarco Interface Unit v2.1
Gasboy CFN Series
Prepare PUMP.BIN data
In PUMP.BIN program menu 3, pump options should be set according to the following chart.
Some prepackaged sets of options may exist there, but many sites will have to add or subtract
options to account for the many variations that may be found. You may have to create some new
pump types to accommodate. Combine all options from this table that apply to give the set of
options for a pump.
Pump, Model or Configuration
Set option(s)
Pump is MPD, Blender, or Salesmaker IV
1 and 5
Pump has cash/credit select buttons
3
Pump is Gilbarco electronic pump
9
Pump is single-sided
15
Pump has press-to-start kit
17
Alert beep is desired before customer presses
payment type key on CRIND
18
Pump has grade select buttons
19
For an ordinary Highline, all you need is option 9. With cash/credit select buttons, you must add
option 3, so that your list is 3 and 9.
For an ordinary MPD, the required options are 1, 5, and 9. With cash/credit select buttons,
you must add option 3, so that your list is 1, 3, 5, and 9.
If you have cash/credit select options installed on any pumps, you must set their fill limits to
$999 and maximum limit to 0. This must be set in pump configuration, and also with the LOAD
CUTOFF command.
Option 6 is also mentioned in PUMP.BIN. You will not need this option.
Advantage Super High special settings
Advantage Super High (model BD1) has the following PUMP.BIN configuration requirements.
Side ‘B’ of the pump must have 2 hoses assigned as illustrated.
In Pump type - submenu 1:
In Pump Control Units - submenu 2:
In Add Pump types - submenu 3:
# Pump type
Cl
Slow
Fill
Max
Pulse
Hoses
1. GILBARCO MPD
1
0.250
$50
0
1000/G
1
2. GILBARCO MPD
1
0.250
$50
0
1000/G
2
1. ELECTRONIC PCU
1:1
2:2
2. ELECTRONIC PCU
1:3
2:4
3. ELECTRONIC PCU
1:5
2:6
#. GILBARCO MPD
(2) 1,5,7,9