Front panel cpu leds – Gasboy Gilbarco Interface Unit User Manual
Page 40
![background image](https://www.manualsdir.com/files/787407/content/doc040.png)
32
Hardware
Gilbarco Interface Unit v2.1
Gasboy CFN Series
Front panel CPU LEDs
The two rows of LEDs visible through the front panel window are shown in figure and their
functions are listed in the figure after that. The upper row LEDs, left to right, are named L1, L2,
and so on through L12. The lower row LEDs, left to right, are named DC, BOK, and BAD.
Lamp
Indication
L1
CRIND RS485/422 Transmit data
L2
CRIND RS485/422 Receive data
L3
Site Controller RS485/422 transmit data
L4
Site Controller RS485/422 receive data
L5
Deadman timer refresh
L6
Current loop power enabled
L7
Current loop #1 active if flashing
L8
Current loop #2 active if flashing
L9
Program fail code bit 1
L10
Program fail code bit 2
L11
Program fail code bit 3
L12
Program fail code bit 4
DC
DC 5V power OK (green)
BOK
Battery OK (green)
BAD
Battery bad (red)
Examination of these lamps allows quick evaluation of the state of the interface. They are
discussed in the Installation chapter.
The "Internal program error" conditions indicate severe hardware failure or software defects
which must be fixed by the developers. Note which lamps were on, and the circumstances such
as what was being done and how often this is seen. If internal program error is not a frequent
event, you may temporarily restore a site to operating condition by cycling power to the interface
box after carefully gathering information. Report any internal program error conditions to
Gasboy Development.
Lamp
L9
L10
L11
L12
Code
Meaning
OFF
OFF
OFF
OFF
0
Normal. Other lamps should blink.
OFF
OFF
OFF
ON
1
Power fail. Problem with AC power detect
OFF
OFF
ON
OFF
2
Internal program error.
OFF
OFF
ON
ON
3
Internal program error.
OFF
ON
OFF
OFF
4
ROM checksum bad. Pin bent on U18-
U21?
OFF
ON
OFF
ON
5
RAM bad. Replace chips U31 and U32.
OFF
ON
ON
OFF
6
Program failure. Replace U18-U20.
OFF
ON
ON
ON
7
Internal program error.
ON
OFF
OFF
OFF
8
Internal program error