beautypg.com

Don’t use gallon limits on multi-fuel pumps, Use $999 limits only with cash/credit select, Use only grade 1 with highlines – Gasboy Gilbarco Interface Unit User Manual

Page 16: Set correct level at price bars, Use reader auto yes only with crinds, Install k5 and k6, Do memory reset before checkout, Starting up the site, Determine programming information

background image

8

Installation

Gilbarco Interface Unit v2.1

Gasboy CFN Series

Don’t use gallon limits on multi-fuel pumps

Multiple hose/fuel pumps may use only dollar limits. The Gasboy equipment does not provide
volume limits for Gilbarco multiple fuel pumps, such as MPDs or blenders. This implies that a
site with any such pumps may not use gallon limits as card limits.

Use $999 limits only with cash/credit select

On pumps with five-dight money configuration, use $999 as a limit only for pumps with cash/
credit buttons. Cash/credit buttons are the flashing buttons located on the pump, not the tender
keys on CRINDs. Never use $995 and above as a card limit.

On pumps with six-dight money configuration, use $9990 as a limit only for pumps with

cash/credit buttons. Cash/credit buttons are the flashing buttons located on the pump, not the
tender keys on CRINDs. Never use $9950 and above as a card limit.

Use only grade 1 with Highlines

Program the pump grade as a Gasboy hose number. Per pump, program the pump assigning grade
1 to hose 1, grade 2 to hose 2, etc.

Set correct level at price bars

If there is cash/credit pricing, make price bars show price level 2. This rule has some exceptions.
See Price level for price bars, below.

Use reader AUTO YES only with CRINDs

Don’t set READER.BIN program menu 3 Auto column (auto pump select) to YES for any reader
that is not a CRIND, CAT, or a DPT. Auto pump select set to YES on an ICR may cause its
representative pump to shut off almost immediately after activation.

Install K5 and K6

Make sure interface unit CPU board K5 and K6 are installed. Everything will seem to work fine
with these missing, until the lights flicker. At that time many unexpected things can happen.

Do memory reset before checkout

Be sure to do a memory reset on the interface after you have all dispensers programmed and
before you try to bring them up.

Starting up the site

Complete each of the following sections. You do not need to complete them in order, but you
should make sure you have considered or performed each item mentioned.

Determine programming information

In this phase you make decisions on programming, options, switch settings, and so on. Some
issues here have consequences with respect to other issues, and you may find you have to
backtrack and change earlier decisions, in order to make later ones work out.

You may need Gilbarco manuals and additional Gasboy manuals to help determine exactly

how to program the things discussed here.

Here is a worksheet. Make copies, and fill out one line per fueling position.