Led display board – Cybex 525AT Arc Trainer User Manual
Page 54

54
55
Cybex Service Manual
2. Pull the white (or red) heart rate wire through the second lowest front hole.
3. Connect the white (or red) heart rate wire to the tab on the front grip.
4. Connect the black heart rate wire to the tab on the back grip.
Do not pinch heart wires or allow contacts to touch each other when installing grips.
5. Install the five screws securing back grip to front grip using a Phillips screwdriver. Do not over
tighten grips.
Complete installation
1. Operate the unit at all levels to verify proper operation.
2. Hold the contact heart rate grips until a heart rate is displayed, typically less than thirty
seconds.
LED Display Board
Tools Required
•
Phillips screwdriver
•
ESD (Electrostatic Discharge) grounding strap.
Disconnect power source
1. Turn the main power switch to the off (O) position.
2. Unplug the power cord from the power outlet.
WARNING: Shock and electrocution hazard
•
Unplug unit and let sit 10 minutes before cleaning or performing maintenance
•
Electrical charge can remain in unit after unplugging
•
Keep water and liquids away from electrical parts
NOTICE:
Component damage
Wear an ESD grounding strap during this procedure. Connect ESD grounding strap to
frame bolts or unpainted metal of frame. If ESD grounding strap is not available, touch
frame bolts or unpainted metal of frame before handling any electronics.