beautypg.com

Cybex service manual – Cybex 525AT Arc Trainer User Manual

Page 47

background image

47

Cybex Service Manual

Connect power cord
Plug the power cord into the power outlet.
Perform calibration procedure

1. Hold the handrails to steady self while stepping into the foot plates.
2. Begin striding.

3. Press and the hold the Display option

MEMBRANE, HANDSET,

ARC, BIKE, TREADMILL,

ENGLISH

B

A

REVISIONS

DESCRIPTION

See sheet 1

ECO

REV

D A TE

APPRO V AL

BY

10 TROTTER DRIVE

MED W A Y , MA

RE V .

SHEET 7 OF 12

SIZE

APPRO V ALS

DR A WN BY

M A TERIAL

FINISH

ADOBE GENER A TED DR A WING

DO NO T MANUAL L Y UPD A TE

CHECKED

RES P ENG

MFG ENG

QUA L ENG

D A TE

DWG. NO.

UNLESS OTHE R WISE SPECIFIED

DIMENSIONS ARE IN INCHES

T OLERANCES ARE :

.XX ± .02

.XXX ± .010

ANGULAR = ± 1°

FINISH = 125 RMS

FRACTIONS = ± 1/64”

SCALE: 1=1

THIS FILE IS IN ADOBE ILLUSTR A T OR

DO NO T SCALE DR A WING

THE INFORM A TION CON T AINED IN THIS DR A WING IS THE SOLE PROPE R T Y OF CYBEX.

AN Y REPRODUCTION IN P A R T OR WHOLE WITHOUT

THE WRITTEN PERMISSION OF CYBEX IS PROHIBITED.

.

.

.

2/7/12

SW-23665-4

LIGHT GREEN PMS 354C (PT-3190)
DARK GREEN PMS 356C (PT-3515)
WHITE (PT-PE01)
YELLOW PMS 142C (PT-2325)

WINDOW DEAD FRONT (PT-3396)
BLACK (PT-PE02)
DARK GRAY PMS 425C (PT-3747)
RED PMS 185C (PT-892)
LIGHT GRAY PMS 424C (PT-2463)
DARK BLUE PMS 2925C
LIGHT BLUE PMS 2905C

RIM /PILLOW EMBOSSED AREAS

EMBOSS

GLOSS AREAS

and

DOWN

keys for 3 seconds.

4. Press QUICK START.

5. Press the ENTER

key three times until “Pivot” is displayed.

6. Stop striding. Wait until foot plates come to a complete stop before dismounting unit. Hold

handrails to steady self while stepping off unit.

7. Press QUICK START to perform calibration. The incline motor will incline to it’s maximum

extension. Stay off footplates until calibration is complete. Incline should be at 20%

(maximum).

8. Press STOP to exit.
9. Hold the handrails to steady self while stepping into the foot plates.
10. Begin striding.
11. Press QUICK START to enter Active Mode.

12. Press incline DOWN

and then incline

UP

to reset inline to 6%.

13. Press STOP to exit. Skip to Install front access cover.

Install front access cover

1. Place front access cover in place.

1

3

2

Description

1

Upper screw (2)

2

Front access cover

3