beautypg.com

Comtech EF Data RCF6001 User Manual

Page 17

background image

RCF6001 Satellite Terminal

Installation

TM082 - Rev. 1.0

Page 2-5

J3 – RS232 Terminal Port

Table 2-2.

J3 - RS232 Terminal Port - 9-Pin Female ‘D’

Pin No.

Signal

Description

Direction

3

TxD

Transmit Data

Output

2

RxD

Receive Data

Input

5

Gnd

Ground

-----

J5 – Alarm Connection
The modem has two form-C dry contact alarm relays onboard and an alarm connector located on the
rear panel, the 9-pin male “D” sub connector J6.

The two relays are designated Modulator Alarm and Demodulator Alarm. Non-Alarm is defined as the
powered state of the relay. Thus, if there is a Modulator Alarm and/or Demodulator Alarm, the pins will
be connected as follows:

Alarm

No Alarm

Modulator

Pins 2 and 3 Shorted

Pins 1 and 2 Shorted

Demodulator

Pins 8 and 9 Shorted

Pin 7 and 8 Shorted

The pin definitions for J5 are shown in Table 2-3 below. Note that the NC and NO (Normally Closed
and Normally Open) nomenclature applies to non-energized relays.

Table 2–3.

J5 - Alarm Connector – 9-Pin Male ‘D’ Sub Connector

J6 Pin Number

Connection

1

Mod Alarm Relay A NO on Alarm

2

Mod Alarm Relay A Common

3

Mod Alarm Relay A NC on Alarm

4

-----

5

AGC Voltage Output

6

Gnd

7

Demod Alarm Relay B NO on Alarm

8

Demod Alarm Relay B Common

9

Demod Alarm Relay B NC on Alarm