Comtech EF Data CDM-625A User Manual
Page 527

CDM-625A Advanced Satellite Modem
MN-CDM625A
CDM-625A ODU (Transceiver, BUC, LNB) Operation
Revision 3
10–59
10.5.1.2.1.3 Home > Outdoor Unit (ODU) > CSAT-5060 > Unit Settings 1/2,
2/2
Open the Unit Settings 1/2 page or the Unit Settings 2/2 page from the nested CSAT-5060
submenu.
The Unit Settings 1/2 page contains the following options:
Hot
Key Dialog Window
Option Entry
A
Unit Mute Mode
Use the ↑↓ arrow keys to select Unmuted After Freq Change or
Muted After Freq Change
B
Unit Auto Fault Recovery
Use the ↑↓ arrow keys to select Disabled or Enabled
C
Unit Cold Start
Use the ↑↓ arrow keys to select Disabled or Enabled
The Unit Settings 2/2 page contains the following options:
Hot
Key Dialog Window
Option Entry
A
Unit Ext Ref Fault Logic
Use the ↑↓ arrow keys to select No Summary or Summary
B
Unit Ref Osc Adjust
Enter a value from 0 to 255
C
Circuit ID
Enter an identifying label for the ODU here
Typical for either page, press a hot key to open a dialog window. Otherwise, press [ESC] to
return to the nested CSAT-5060 submenu.