Comtech EF Data CDM-625A User Manual
Page 341

CDM-625A Advanced Satellite Modem
MN-CDM625A
Serial-based Remote Product Management
Revision 3
8–29
Parameter
Command
(Instruction
& Qualifier)
Length of
Arguments
Description of Arguments
Response to
Command
Query
(Instruction &
Qualifier)
Response to Query
One Time
EDMAC Slave
Overwrite
OTO=
1 byte, 0 or 1
Command or Query.
Sets or returns One Time Overwrite to EDMAC Slave modem in the form x, where:
0=Off
1=On
Example 1: OTO=0 disables One Time Overwrite – EDMAC Slave modem may only remotely accept EDMAC command
from EDMAC Master modem.
Example 2: OTO=1 enables One Time Overwrite – EDMAC Slave modem may locally accept ONE remote control
command.
OTO=
OTO?
OTO*
OTO#
OTO?
OTO=x
(see Description of
Arguments)
External
Frequency
Reference
EFR=
Exception –
600L Emulation:
MRC=
1 byte, 0 thru 6
Command or Query.
Sets or returns the External Frequency Reference in the form x, where:
0=Internal 10MHz (DEFAULT)
1=External 1 MHz
2=External 2 MHz
3=External 5 MHz
4=External 10 MHz
5=spare
6=Internal 10MHz plus output (this means that the Reference is available on the “Ext Ref” rear connector (small
rear-panel LED indicates when ON))
EFR=
EFR?
EFR*
EFR#
Exception –
600L Emulation:
MRC=
MRC?
MRC*
MRC#
EFR?
Exception –
600L Emulation:
MRC=?
EFR=x
(see Description of
Arguments)
Exception –
600L Emulation:
MRC=x
Adjustment for
Internal 10MHz
High- stability
Reference
ADJ=
4 bytes, numeric Command or Query.
Sets or returns fine adjustment of the Internal 10MHz Reference on the High-Stability Frequency Reference module in the
form sddd, where:
s=sign (+ or –)
ddd=Value, 0-999.
ADJ=
ADJ?
ADJ*
ADJ#
ADJ?
ADJ=sddd
(see Description of
Arguments)
Warm-up Delay WRM=
1 byte, 0 or 1
Command or Query. (Hi-Stability Frequency Reference parameter)
Sets or returns the High-Stability Frequency Reference warm-up delay parameter in the form x, where:
0=Delay off (instant on)
1=Warm-up Delay on
WRM=
WRM?
WRM*
WRM#
WRM?
WRM=x
(see Description of
Arguments)
Countdown of
Warm-up Delay
remaining
CTD=
3 bytes, numeric Command or Query. (Hi-Stability Frequency Reference parameter)
Sets or returns the High-Stability Frequency Reference countdown parameter in the form xxx, where:
xxx=countdown of the number of seconds remaining of the Warm-up time.
Note: As a command, the only permitted format is CTD=000, which abandons the delay.
CTD=
CTD?
CTD*
CTD#
CTD?
CTD=xxx
(see Description of
Arguments)
Unit Test Mode TST=
1 byte, 0 thru 6
Command or Query.
Unit Test Mode, where:
0=Normal Mode (no test)
1=Tx CW
2=Tx Alternating 1,0 Pattern
3=IF Loopback
4=RF Loopback
5=Digital Loopback
6=I/O Loopback
Example: <0/TST=3 (IF Loopback)
TST=
TST?
TST*
TST#
TST?
TST=x
(see Description of
Arguments)