MN-CDM625A
CDM-625A ODU (Transceiver, BUC, LNB) Operation
Revision 3
10–31
ODU: FSK-control BUC Advanced-FSK LPOD (2LPODs
Online/Offline LPOD) Statistics Config
Stats: Logging=Enabled Interval=10 min
Averaging=Disabled Clear-All=No (◄ ►)
Use the
▲▼
arrow keys to select Logging, Interval, Averaging, or Clear-All, and then use the
▲▼
arrow keys to set that setting:
Selection
Setting
Logging
Enabled or Disabled.
Interval
The Logging Interval is the period of time over which performance statistics are
measured. Set this interval as 00 to disable the feature (i.e., no logging) or,
otherwise, define the logging interval from 10 through 90 minutes in 10-minute
increments.
Averaging
Enabled or Disabled.
Clear-All
When prompted, select YES.
Press ENTER when done.
ODU: FSK-control BUC Advanced-FSK LPOD (2LPODs
Online/Offline LPOD) Statistics Stored-Statistics
To enable statistics logging, see the LPOD Statistics: Config menu. As statistics are compiled,
the Stored-Statistics screen appears as shown here:
Reading Stored Stats..... Please Wait
Once the statistics are compiled, the Stored-Statistics screen displays this data as shown here:
Stats001: 000.0C 040.0C 20.45dBm 10.00dB
10/01/10 12:52:08 On On Off 001.0 002.3V
Use the
▲▼
arrow keys to scroll backwards or forwards through the statistics log entries.
The top line displays:
• The statistics log entry number (up to 512 entries may be stored)
• Operating Temperature
• Amplifier Temperature
• Power