beautypg.com

1 optional dc operation – cdm-625a accessories, 2 optional dc operation – apply power – Comtech EF Data CDM-625A User Manual

Page 105

background image

CDM-625A Advanced Satellite Modem

MN-CDM625A

Rear Panel Connectors and Pinouts

Revision 3

3–21

3.3.3.1 Optional DC Operation – CDM-625A Accessories

Contact Comtech EF Data Product Support to purchase any of these available accessories:

CEFD P/N

Description

KT-0020683

DC to AC Conversion Kit for CDM-625A Base Modem

KT-0020777

DC to AC Conversion Kit for CDM-625A with IP Packet Processor

KT-0020692

DC Primary Power Supply: -48 VDC, w/required cables

PS-0020519

DC 48V 120W Power Supply

PS-0020504

DC 24V 120W Power Supply

CA-0000455

DC Pigtail Adapter

3.3.3.2 Optional DC Operation – Apply Power

Figure 3-13. Apply Power to the CDM-625A Optional DC Chassis

To apply DC power to the CDM-625A, do these steps:

• First, connect the user-supplied (+) and (–) DC power leads to their respective terminals.

Number 18 AWG minimum wires are recommended.

• Then, connect the user-supplied DC power leads to the power source.

• Finally, switch the unit ON.